Compartilhamento |
![]() ![]() |
Use este identificador para citar ou linkar para este item:
http://www.bdtd.ueg.br/handle/tede/1653
Tipo do documento: | Dissertação |
Título: | Projeto e construção de túnel de vento para ensaios de deposição de deriva associados à bioinseticida, adjuvantes e velocidades do vento |
Título(s) alternativo(s): | Design and construction of a wind tunnel for drift deposition tests associated with bioinseticide, adjuvants and wind speeds |
Autor: | Lima, Victor Hugo Almeida ![]() |
Primeiro orientador: | Reis, Elton Fialho dos |
Primeiro membro da banca: | Delmond, Josué Gomes |
Segundo membro da banca: | Delmond, Josué Gomes |
Terceiro membro da banca: | Lopes, Arthur Gabriel Caldas |
Resumo: | É essencial a realização de pesquisas que propiciem a correta pulverização de defensivos, naquantidade necessária, de forma econômica e com o mínimo de contaminação. Nesse contexto,objetivou-se avaliar, em túnel de vento, a deposição e deriva de calda de pulverização emdiferentes condições de velocidades do vento. Para isso, o presente trabalho foi dividido em trêscapítulos denominados de, respectivamente, “Dimensionamento, construção e validação de umtúnel de vento de circuito aberto para estudo aerodinâmico da pulverização agrícola”; “Influênciada intensidade do vento na deriva de pulverizações simuladas em túnel de vento” e “ModelagemGeoestatística da influência de adjuvantes e velocidades do vento na deposição de deriva emaplicações de bioinseticida em túnel de vento”. Os experimentos foram conduzidos naUniversidade Estadual de Goiás. Foi projetado e construído um Túnel de vento de circuito aberto,composto por ventilador axial, câmara de estabilização, bocal, seção de teste e difusor. Para avalidação foram calculados parâmetros aerodinâmicos e a análise foi realizada por estatísticadescritiva. A pesquisa sobre a influência da velocidade do vento nos depósitos de deriva emdiferentes distâncias horizontais, realizada em túnel de vento, foi conduzida em delineamentointeiramente casualizado, em esquema fatorial 5 x 4 (velocidades do fluxo de ar x distânciashorizontais a favor do vento). O estudo da influência de adjuvantes e intensidade da velocidadedo vento na deposição de calda e deriva em aplicações simuladas com bioinseticida a base deBacillus thuringiensis foi realizado em túnel de vento, em delineamento inteiramente casualizadono esquema fatorial 5 x 4 x 4. Os tratamentos foram constituídos por cinco distâncias horizontaisa favor do vento (0,45m; 0,75m; 1,05m; 1,35m e 1,65m), quatro velocidades do vento (1 m s-1, 2m s-1, 3 m s-1e 4 m s-1) e 4 formulações de calda (Água, Dipel®, Dipel® + Veget'Oil® Dipel® +Break Thru®). Em ambos os capítulos, a deposição de deriva foi coletada utilizando alvosartificiais posicionados transversalmente ao fluxo do vento. Os dados foram obtidos porespectrofotometria e foram submetidos à análise de variância (P<0,05) e quando significativosforam aplicados o Teste de Tukey e regressão, ambos a 5% de probabilidade. Para as análisesforam utilizados os softwares R e Sisvar. Para a análise geoestatística foi utilizado o softwareGS+ Versão 7®. O túnel opera em boas condições, possui escoamento laminar, incompressível eo fluxo do vento apresentou baixa variação entre os pontos. A deposição de calda foi maior paradistâncias mais próximas do local de pulverização. Velocidades mais altas possibilitaram obtermaiores depósitos de deriva. O uso do adjuvante Break Thru® favoreceu menor perda por derivanos terços superior e médio. Para o terço inferior, na velocidade de 1 m s-1, a adição do adjuvanteBreak Thru® reduziu a deriva, mas a 4 m s-1 o uso de adjuvantes não promoveu a redução dadeposição em relação a calda preparada com o inseticida biológico. A variável analisadaapresentou alto grau de dependência espacial para todos os tratamentos. |
Abstract: | It is essential to carry out research that provides the correct supply of pesticides, in the necessaryquantity, in an economical way and with minimum contamination. In this context, the objectivewas to evaluate, in a wind tunnel, the position and drift of precipitation in different wind speedconditions. To this end, the present work was divided into three chapters called, respectively,“Sizing, construction and validation of an open circuit wind tunnel for the aerodynamic study ofagricultural spraying”; “Influence of wind intensity on spray drift simulated in a wind tunnel”and “Geostatistical modeling of the influence of adjuvants and wind speeds on drift deposition inbioinsecticide applications in a wind tunnel”. The experiments were extended at the StateUniversity of Goiás. An open circuit wind tunnel was designed and built, comprising an axialfan, stabilization chamber, nozzle, test section and diffuser. For validation, aerodynamicparameters were calculated and the analysis was performed using descriptive statistics. Researchon the influence of wind speed on drift deposits at different horizontal distances, carried out in awind tunnel, was conducted in a completely randomized design, in a 5 x 4 factorial scheme (airflow velocities x horizontal distances downwind). The study of the influence of adjuvants andwind speed intensity on spray deposition and drift in simulated applications with bioinsecticidebased on Bacillus thuringiensis was carried out in a wind tunnel, in a randomized design in a 5 x4 x 4 factorial scheme. The treatments consisted of five horizontal distances downwind (0.45m;0.75m; 1.05m; 1.35m and 1.65m), four wind speeds (1 m s-1, 2 m s- 1, 3 m s-1and 4 m s-1) andfour spray formulations (Water, Dipel®, Dipel® + Veget'Oil® Dipel® + Break Thru®). In bothchapters, drift deposition was collected using artificial targets positioned transverse to the windflow. The data were obtained by spectrophotometry and were subjected to analysis of variance(P<0.05) and when significant, the Tukey test and regression were applied, both at 5%probability. The software R and Sisvar were used for the analyses. For geostatistical analysis, theGS+ Version 7® software was used. The tunnel operates in good conditions, has laminar,incompressible flow and the wind flow showed low variation between points. Spray depositionwas greater at distances closer to the spraying site. Higher speeds made it possible to obtain largerdrift deposits. The use of Break Thru® adjuvant favored less loss due to drift in the upper andmiddle thirds. For the lower third, at a speed of 1 m s-1, the addition of Break Thru® adjuvantreduced drift, but at 4 m s-1the use of adjuvants did not promote a reduction in deposition inrelation to the mixture prepared with the insecticide. biological. The analyzed variable showed ahigh degree of spatial dependence for all treatments. |
Palavras-chave: | Tecnologia de aplicação Bacillus thuringiensis Bioinsumos Velocidade do vento Application technology Bacillus thuringiensis Bioinputs Wind speed |
Área(s) do CNPq: | CIENCIAS AGRARIAS::ENGENHARIA AGRICOLA |
Idioma: | por |
País: | Brasil |
Instituição: | Universidade Estadual de Goiás |
Sigla da instituição: | UEG |
Departamento: | UEG ::Coordenação de Mestrado em Engenharia Agrícola |
Programa: | Programa de Pós-Graduação Stricto sensu em Engenharia Agrícola |
Citação: | LIMA, V. H. A. Projeto e construção de túnel de vento para ensaios de deposição de deriva associados à bioinseticida, adjuvantes e velocidades do vento. 2023. 88 f. Dissertação (Mestrado em Engenharia Agrícola) - Câmpus Central - Sede: Anápolis - CET - Henrique Santillo, Universidade Estadual de Goiás, Anápolis, GO . |
Tipo de acesso: | Acesso Aberto |
URI: | http://www.bdtd.ueg.br/handle/tede/1653 |
Data de defesa: | 22-Nov-2023 |
Aparece nas coleções: | Mestrado em Engenharia Agrícola |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
VICTOR HUGO ALMEIDA LIMA_DISSERTAÇÃO_EA.pdf | Dissertação_Mestrado em Engenharia Agrícola | 1,84 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
VICTOR HUGO ALMEIDA LIMA_TERMO DE AUTORIZAÇÃO.pdf | Termo de Autorização | 231,77 kB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.