Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://www.bdtd.ueg.br/handle/tede/173
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Camargo, Rubia de Pina Luchetti C | - |
dc.contributor.advisor1 | Costa, Orlene Silva da | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/2724089948633539 | por |
dc.contributor.referee1 | Oliveira, Sérgio Botelho de | - |
dc.contributor.referee2 | Sandri, Delvio | - |
dc.date.accessioned | 2020-03-20T19:44:56Z | - |
dc.date.issued | 2011-02-01 | - |
dc.identifier.citation | CAMARGO, Rubia de Pina Luchetti C. Estudo dos resíduos gerados na eta de anápolis-go: caracterização e quantificação. 2011. 89 f.. Dissertação (Mestrado em Engenharia Agrícola) - Câmpus Central - Sede: Anápolis – CET, Universidade Estadual de Goiás, Anápolis. | por |
dc.identifier.uri | http://www.bdtd.ueg.br/handle/tede/173 | - |
dc.description.resumo | As Estações de Tratamento de Água (ETA), também consideradas indústrias de transformação, geram resíduos como o lodo dos decantadores e a água de lavagem dos filtros, que precisam necessitam tratamento e disposição correta a fim de evitar qualquer tipo de contaminação ou de geração de impactos negativos ao meio ambiente. A Estação de Tratamento de Água de Anápolis não possui nenhuma informação sobre seus resíduos, sendo necessário um estudo para formação de um banco de dados para possibilitar futuros estudos de tratamento, disposição ou utilização desses resíduos, como forma de minimizar os impactos na geração pelos resíduos de ETA, melhorando a sustentabilidade do sistema. Esse trabalho teve o objetivo de estudar a caracterização física, química e bacteriológica e de quantificação dos resíduos gerados na ETA de Anápolis, que é de ciclo completo e realiza descargas diárias de seus resíduos. A caracterização e a quantificação dos resíduos foram realizadas por meio de seis coletas do lodo dos decantadores e da água de lavagem dos filtros, entre os meses de agosto de 2010 a janeiro de 2011. As amostras de lodo foram obtidas na descarga do lodo em uma canaleta lateral aos decantadores, e a água de lavagem foi coletada no próprio filtro, durante a lavagem, sendo formadas sempre amostras compostas. A água bruta de captação do Ribeirão Piancó, também foi analisada durante o mesmo período, para analisar e comparar com os resultados obtidos das análises dos resíduos. Analisou-se para caracterização: cor aparente, turbidez, pH, alcalinidade, condutividade, temperatura, demanda química de oxigênio, oxigênio dissolvido, acidez total, sólidos totais, sólidos suspensos, sólidos dissolvidos totais, metais (alumínio, ferro e manganês), coliformes totais e Escherichia coli. A quantificação do lodo foi realizada utilizando-se as fórmulas empíricas sugeridas por Kawamura, Cornwell, Richter, AWWA e WRC, e a água de lavagem do filtro foi quantificada por um medidor de vazão ultrassônico na própria ETA. A caracterização dos resíduos demonstrou que o lodo não pode ser disposto em corpo d’água sem receber tratamento adequado por possuir alta concentração de metais (alumínio e ferro) e grande quantidade de sólidos sedimentáveis, acima do permitido pela Resolução Conama n° 357/2005. A vazão (890 L.s-1) da ETA está acima da projetada (máx. 800 L.s-1), reduzindo sua eficiência, sobrecarregando os filtros, necessitando um aumento na frequência de limpeza dos mesmos, gerando em média uma perda de 1200 m3 de água potável diariamente. A água de lavagem do filtro pode ser reutilizada na própria ETA, retornando para o início do processo de tratamento se a mesma tiver as características da água de captação (Classe 2). O estudo demonstrou que alguns parâmetros estão acima do aceitável como: turbidez (média de 113 uT) e a quantidade de metais presente (média alumínio 12,5 mg.L-1 e ferro 14,9 mg.L-1), sendo necessário um estudo para otimização do processo, que garanta que estas características estejam dentro do padrão permitido. As análises da água bruta demonstraram em alguns parâmetros como a série de sólidos, a tendência de crescimento do período de seca para chuva, podendo sobrecarregar o sistema afetando a eficiência do processo. O índice de sedimentabilidade do lodo (ISL) está diretamente relacionado aos sólidos dissolvidos totais (SDT) da água de lavagem dos filtros, pois a alta velocidade de decantação reduz a passagem de SDT para os filtros. | por |
dc.description.abstract | The Water Treatment Plant (WTP), also considered processing industries, generate waste like the sludge from the clarifiers and backwash water from filters, which need proper treatment and disposal in order to avoid any contamination or generation of negative impacts on the environment. The Anápolis Water Treatment Plant has no information on their waste, being necessary a study to form a database to allow future studies of treatment, or use of these wastes to minimize impacts on waste generation by WTP, improving the sustainability of the system. This work aimed to study the physical, chemical and bacteriological and quantification of waste generated at the Anápolis WTP, which has a full cycle and performs a daily discharge of its waste. The characterization and quantification of waste was conducted by means of six samples of sludge from clarifiers and filter backwash water, between the months of August 2010 to January 2011. The sludge samples were obtained in the sludge discharge in a lateral channel next to the decanters, and backwash water was collected on the filter itself during washing, always forming composite samples. The catchment of raw water from Piancó Creek (Ribeirão Piancó) was also analyzed during the same period, to analyze and compare the results of waste analysis. For characterization, the following were analyzed: apparent color, turbidity, pH, alkalinity, conductivity, temperature, chemical oxygen demand, dissolved oxygen, acidity, total solids, suspended solids, total dissolved solids, metals (aluminum, iron and manganese), total coliform and Escherichia coli. Quantification of sludge was performed using the empirical formulas suggested by Kawamura, Cornwell, Richter, AWWA and WRC, and the filter backwash water was quantified by an ultrasonic flow meter in the WTP itself. The waste characterization showed that the sludge cannot be put into a water body without receiving adequate treatment because of its high concentration of metals (aluminum and iron) and large amount of settleable solids, above those permitted by CONAMA Resolution Nº. 357/2005. The WTP flow (890 L.s-1) is above the projected (max. 800 L.s-1), reducing its efficiency, overloading the filters, requiring an increase in the frequency of cleaning them, generating a daily average loss of 1200 m3 of drinking water. The filter backwash water can be reused in the WTP itself, returning to the beginning of the treatment process if it has the characteristics of the water catchment (Class 2). The study showed that some parameters are above acceptable, for example: turbidity (average113 NTU) and the amount of metals present (average 12.5 mg.L-1 aluminum and iron 14.9 mg.L-1), requiring a study to optimize the process, ensuring that these characteristics are within the permitted standard. The analysis of the raw water showed in some parameters such as the solid series, the growth tendency of drought to rain, which can overload the system affecting the efficiency of the process. The rate of sludge settling (RSS) is directly related to the total dissolved solids (TDS) of the filter water washing because the high rate of sedimentation reduces the passage of TDS to the filters. | eng |
dc.description.provenance | Submitted by Sandra Barbosa (sandrabarbosa632@gmail.com) on 2020-03-20T14:10:12Z No. of bitstreams: 2 license.txt: 2134 bytes, checksum: 4709595c927233fc684151cf6f2010cf (MD5) DISSERTAA‡AƒO_RUBIA.pdf: 2340820 bytes, checksum: 705c42711969b9b052876c8f78dbeae6 (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2020-03-20T19:44:56Z (GMT). No. of bitstreams: 2 license.txt: 2134 bytes, checksum: 4709595c927233fc684151cf6f2010cf (MD5) DISSERTAA‡AƒO_RUBIA.pdf: 2340820 bytes, checksum: 705c42711969b9b052876c8f78dbeae6 (MD5) Previous issue date: 2011-02-01 | eng |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES | por |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Universidade Estadual de Goiás | por |
dc.publisher.department | UEG ::Coordenação de Mestrado em Engenharia Agrícola | por |
dc.publisher.country | Brasil | por |
dc.publisher.initials | UEG | por |
dc.publisher.program | Programa de Pós-Graduação Stricto sensu em Engenharia Agrícola | por |
dc.rights | Acesso Aberto | por |
dc.subject | Lodo | por |
dc.subject | Decantadores | por |
dc.subject | Água de lavagem e filtros | por |
dc.subject | Sludge, , backwash water and filters | eng |
dc.subject | Clarifiers | eng |
dc.subject | Backwash water and filters. | eng |
dc.subject.cnpq | CIENCIAS AGRARIAS::ENGENHARIA AGRICOLA | por |
dc.subject.cnpq | ENGENHARIAS::ENGENHARIA SANITARIA | por |
dc.title | Estudo dos resíduos gerados na eta de anápolis-go: caracterização e quantificação | por |
dc.type | Dissertação | por |
Aparece nas coleções: | Mestrado em Engenharia Agrícola |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
DISSERTAA‡AƒO_RUBIA.pdf | 2,29 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.